BKPXS - TEFLON TOPCOAT, 455-115

Product Identification

Product ID:TEFLON TOPCOAT, 455-115
MSDS Date:01/01/1987
FSC:8010
NIIN:00N015192
MSDS Number: BKPXS

Responsible Party
E I DUPONT DE NEMOURS & CO
FINISHES & FABRICATED PRODUCTS DEPT
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)

Info Phone: 800-441-7515

Cage: 0ERJ7

Contractor
E.I. DUPONT DE NEMOURS & CO
WILMINGTON, DE 19898 US

Telephone: 800-441-7515;800-441-9442

Cage: 18873

Ingredients

NAUS & LOSS OF CONSCIOUSNESS. RPTS HAVE ASSOCIATED

RTECS: 9999999ZZ


CONT MAY CAUSE SKIN IRRIT

RTECS: 9999999ZZ


NO KNOWN HAZ W/NORMAL INDUSTRIAL USE. IN A

RTECS: 9999999ZZ


SOME RATS EXPOSED TO 250 MG/M3 RESP TITANIUM DUST.

RTECS: 9999999ZZ


LUNGS SHOWED THAT THE LUNG CLEARANCE MECHANISM WAS

RTECS: 9999999ZZ


MG/M3 LEVEL ARE NOT RELEVANT TO WORKPLACE. SUPP

RTECS: 9999999ZZ


VENT. AT TEMPS ABOVE 400C (750F) SM AMTS OF

RTECS: 9999999ZZ


INCR. HYDROGEN FLUORIDE IS TOXIC & CAN CAUSE SKIN &

RTECS: 9999999ZZ


CAUSE LUNG DMG, PULM EDEMA/BURNS. SOME VEGETATION

RTECS: 9999999ZZ


MUST BE GIVEN TO EXHAUST LOCATIONS. OXIDES OF HEAVY

RTECS: 9999999ZZ


FLUOROPOLYMER SOLIDS


0.01.

CAS: 112-34-5

RTECS: KJ9100000


0.01.

CAS: 102-71-6

RTECS: KL9275000


5.

CAS: 64742-95-6


OCTYLPHENOXYPOLYETHOXYETHANOL (NON-IONIC SURFACTANT).


TITANIUM DIOXIDE

CAS: 13463-67-7

RTECS: XR2275000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


CONSCIOUS. CAUSES EYE CORROSION & PERM

RTECS: 9999999ZZ


IRRIT. RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN IRRIT &

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: NORMALLY NOT A HAZ. THESE PRODS
CONTAIN SM AMTS OF SOLV AS DESCRIBED BELOW. SKIN/EYE: MAY CAUSE
IRRIT/BURNING OF EYES. RPTD/PRLNGD LIQ CONT MAY CAUSE SKIN IRRIT
W/DISCOMFORT & DERMAT. OTHER POT ENTIAL HAZ INCLUDE: ING 1: SEE HAZ
DECOMP. ING 2: MAY CAUSE EYE IRRIT W/DISCOMFORT, TEARING OR (SEE
EFTS OF OVEREXP)
Explanation of Carcinogenicity:NONE SPECIFIED BY MANUFACTURER.
Effects of Overexposure:HLTH HAZ: BLURRED VISION. CONT MAY CAUSE SKIN
IRRIT W/DISCOMFORT/RASH. CAN BE ABSORBED THRU SKIN IN HARMFUL AMTS.
MAY CAUSE ABNORMAL KIDNEY FUNC. ING 3: OVEREXP MAY CAUSE EYE, NOSE
& THROAT IRRIT. RPT D/PRLNGD LIQ CONT MAY CAUSE SKIN IRRIT &
DERMAT. MAY CAUSE CNS EFTS SUCH AS DIZZ, HDCH, NAUS & LOSS OF (SEE
ING 7)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: INHAL OF VAP/SPRAY MIST, REMOVE TO FRESH AIR. IF NOT
BRTHG, GIVE ARTF RESP, PREF MOUTH-TO-MOUTH. IF BRTHG DIFFICULTY
PERSISTS/OCCURS LATER, SEE MD. SKIN/EYE: EYE CONT: IMMED FLUSH
W/PLENTY OF W ATER FOR AT LEAST 15 MIN. CALL MD. SKINCONT: WASH
W/SOAP & WATER. IF IRRIT OCCURS, CALL MD. INGEST: GI DISTRESS. IN
UNLIKELY EVENT OF INGEST, CALL MD IMMED & HAVE NAMES OF INGRED
AVAILABLE.

Fire Fighting

Flash Point:NONE
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
WATER FROM FOG NOZZLES MAY BE USED TO COOL CLOSED CONTAINERS TO
PREVENT PRESS BUILD-UP.
Unusual Fire/Explosion Hazard:HYDROGEN FLUORIDE IS RELEASED DURING A
FIRE.

Accidental Release

Spill Release Procedures:VENT AREA. REMOVE SOURCES OF IGNIT. AVOID SKIN
CONT AND BREATHING OF VAPOR. CONFINE AND REMOVE WITH INERT
ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:OBSERVE LABEL PREC. KEEP AWAY FROM
HEAT, SPARKS & FLAME. CLOSE CNTNR AFTER EACH USE. GROUND CNTNRS
WHEN POURING. DO NOT STORE ABOVE 120F. (OTHER PREC)
Other Precautions:HNDLG/STOR PREC: EXPLOSIVE RXN MAY OCCUR ABOVE 796F
W/FINELY DIVIDED FLUOROCARBON & METAL POWDER (ALUMINUM OR
MAGNESIUM). OPERATIONS SUCH AS GRINDING, BUFFING OR GRIT BLASTING
MAY GENERATE SUCH MIXTUR ES. KEEP WET. USE ADEQ VENT TO CONTROL.

Exposure Controls

Respiratory Protection:DO NOT BREATHE VAPORS/MISTS. WEAR A PROPERLY
FITTED NIOSH/MSHA APPROVED VAPOR/PARTICULATE RESPIRATOR FOR USE
WITH PAINTS DURING APPLICATN AND UNTIL ALL VAPS AND SPRAY MIST ARE
EXHAUSTED. FOLLOW RESP M FR DIRECTIONS FOR RESP USE.
Ventilation:PROVIDE SUFFICIENT VENT IN VOLUME & PATTERN TO KEEP
CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING AND SMOKING.
Supplemental Safety and Health
% VOLAT: 46.3-49.1 (WT). HAZ DECOMP PRODS: THESE SYMPTOMS DO NOT
ORDINARILY OCCUR UNTIL SEV HRS AFTER EXPOS & PASS WITHIN 36-48 HRS.
EFTS ARE NOT CUMULATIVE. EXPOS USUALLY RESULTS FROM SMOKING TOBACCO
/CIGARETTES CONTAM W/FLUOROCARBON DURING HANDLING/FROM BRTHG VAPS
EMITTED DURING BAKING. DO NOT EXCEED REC (SEE ING 14)

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SEE INGRED
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:APPRECIABLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:EXPOS TO TEFLON DECOMP PRODS CAN
CREATE INFLUENZA-LIKE SYMP, COMMONLY REFERRED TO AS POLYMER FUME
FEVER. (SEE SUPP DATA)

Disposal

Waste Disposal Methods:DO NOT ALLOW MATL TO CONTAMINATE GROUND WATER
SYSTEMS. SEND TO HAZ WASTE WATER TREATMENT PLANT OR INCINERATE
ABSORBED MATL IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
REQUIREMENTS. DO NOT INCINERATE I N CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.